SENSIT GOLD 2 (G2)

The SENSIT® GOLD 2 (G2) is designed for identifying, pinpointing, and grading above & below ground gas leaks alongside use in confined space applications. The GOLD 2 can also be used for pipeline purging and for inert gas operations to detect combustible gases in oxygen-free environments. The GOLD 2 includes the following features:

|   Readings in PPM, LEL, and/or %VOL

|   Methane & Propane Selectable

|   Audible/Visual Alarm & Tick Mode

|   Configurable Up To 4 Gases

|   Alkaline Batteries

Downloads

Want to Learn More?

Introduction

SENSIT GOLD 2 (G2) Multi-Gas Detector is designed for quick pinpointing of even the smallest gas leaks. It is also ideal for locating and grading above and below ground leaks as well as monitoring confined spaces.

The instrument can be configured for combustible gas readings in PPM, LEL and/or percent volume, and various toxic gases and oxygen.

The SENSIT GOLD 2 (G2) applications include detecting combustible gas leaks, odor response investigations, underground leak pinpointing, carbon monoxide investigations, confined space monitoring, combustible gas measurements, pipeline purging, method 21 emissions testing, and inert gas operations.

Need rechargeable batteries, on-board GPS and enhanced datalogging? Compare with the SENSIT GOLD 3.

Displays Up To 4 Gases Simultaneously

SENSIT GOLD 2 (G2) is fast, accurate, durable, and easy to use and maintain. It can display up to four gases simultaneously, including:

  • LEL (% volume and PPM optional)
  • Oxygen
  • Carbon Monoxide
  • Hydrogen Sulfide
  • Hydrogen Cyanide

It also has selectable combustible gas types, such as methane (natural gas) and propane.

Standard Features

It has several standard features:

  • Class 1 Division 1 Intrinsically Safe Design
  • Internal Pump for Fast Sampling
  • Audible “Tick” Control for Fast Leak Pinpointing
  • LED Warning Lights
  • Backlit Graphic Display
  • Loud Audible Alarm
  • Battery Strength Indicator
  • Internal Memory

Certifications

It is certified by ATEX and UL.

Related Product Videos

Technical Specification

Additional information

Sensor Types

PPM, LEL, % NAT GAS, % Propane, O2, CO, H2S, HCN

Gases

Propane, Oxygen, Carbon Monoxide, Hydrogen Sulfide, Hydrogen Cyanide

Measurement Range

PPM – 0-10,000 ppm
LEL – 0-100% LEL
% NAT GAS – 5-100% GAS
% Propane – 2.2-100% GAS
CO – 0-2,000 ppm
O2 – 0-25% VOL
H2S – 0-100 ppm
HCN – 0-30 ppm

Resolution

PPM – 1 ppm (0- 5,000 ppm), 10 ppm (5,000 – 50,000 ppm); 0.1% LEL; 0.1% VOL;
% NAT GAS – 0.1%
% Propane – 0.1%
O2 – 0.1% VOL;
CO – 1 ppm;
H2S, HCN – 1 ppm (default) or 0.1 ppm

Accuracy

PPM – ±10% or 500 ppm* / 1% LEL*
% NAT GAS – ±5%
O2 – ±10% or 0.2% VOL
CO – ±5% or 5 ppm*
H2S – ±5% or 2 ppm*
HCN – ±5% or 1 ppm*
* = whichever is greater

Battery Type

Alkaline

Battery Life

Approx. 18 hrs continuous

Size

11.5” x 3” x 2.32” (29.2 x 7.6 x 5.9 cm)

Weight

1.2 lb. (544 g)

Operating Temperature

–4°F to 104°F (–20°C to 40°C)

Storage Temperature

–13°F to 149°F (–25°C to 65°C)

Data Storage Capacity

100 Instant Event Saves
1600 Auto Log Saves
100 Bar Hole Tests

Common Accessories

Case & Carrying

Cylinders

Electronics

Filters

Probe & Hose Assembly

Regulator & Adapter

Sensors

CO SensorCO Sensor375-COAF-01VIEW
H2S SensorH2S Sensor375-H2SA1-01VIEW
HCN SensorHCN Sensor375-HCNA1-01VIEW
O2 SensorO2 Sensor375-O2A3-01VIEW
PlaceholderTC Sensor884-STC05VIEW

Misc.