How to Tell Natural Gas from Biogenic Gas in the Field, and What the Wrong Answer Costs
A methane reading does not tell you where the methane came from. Swamps, sewers, landfills and wastewater all produce methane, and a sensitive survey instrument reads it exactly as it reads a pipeline leak. Each of those indications still costs a dispatch, a technician’s time and sometimes an excavation. The fix is a second measurement. Pipeline natural gas carries ethane; biogenic methane carries little or none. Testing for ethane at the point of investigation turns “there is methane here” into “this is (or is not) our gas.”
⅓ to ⅔
Street-level methane indications attributed to non-pipeline sources in published studies.
$110 - $1,000
Estimated cost of one investigation that finds no leak.
$2,300 - $10,000
Estimated cost of one dig that finds no leak.
250 ppb
Ethane the SENSIT IRED confirms in a 50 ppm methane sample.
At $10,000–20,000, the IRED covers its cost after roughly 1 to 5 avoided dry digs on paved streets, or as few as 10 avoided dry investigations.
Because your instrument is doing its job. A methane detector reports methane, and methane has many sources besides your pipe. As survey tools get more sensitive, they find more of all of it.
Biogenic methane comes from microbes breaking down organic matter without oxygen. Common sources along a utility right-of-way include sewer lines and manholes, storm drains, wetlands, buried organic fill, landfills and wastewater plants. To a methane-only instrument, this gas looks identical to a leak.
Two peer-reviewed studies show the scale. In a 2020 street-level survey of Hamburg and Utrecht, researchers used ethane ratios and isotopes to attribute each methane indication. About one-third of the indications in Hamburg and two-thirds in Utrecht were of fossil origin, and the smaller indications in Hamburg were often biogenic. An aircraft study of seven U.S. cities found that natural gas made up 20% to 80% of urban methane emissions in summer, when biogenic emissions rise.
SENSIT’s own customer conversations point the same way. Customers report that as little as 30% of the potential methane they identify is not from a true, gradable source, and one utility reported that about 4 in 10 of its excavations were not related to natural gas. These are customer-reported figures, not a controlled study. We include them because they sit inside the range the published research would predict.
Gas migration is the second cause. Real natural gas follows the easiest path through backfill, conduit and frost layers, and it can surface well away from the fault. A crew can confirm the gas is real and still dig in the wrong place.
Ambiguous readings are the third. Low or intermittent concentrations, shifting wind and overlapping sources leave a number that neither confirms nor clears a leak. Without a test that identifies the source, ambiguity defaults to escalation: another visit, a bar-hole survey or a dig.
The federal picture is unsettled. PHMSA released a final Gas Pipeline Leak Detection and Repair rule on January 17, 2025, which would have required advanced leak detection programs and set leak grading and repair timelines.
States are moving on their own. Public Utilities Commissions are adopting advanced leak detection rules.
Whatever happens federally, the practical trend is the same. Utilities are adopting more sensitive survey technology, and more sensitive surveys produce more indications to investigate. A growing share of those indications will not be natural gas.
Test for ethane. If a methane sample also contains ethane in the right proportion, it is almost certainly pipeline gas. If it contains methane but no ethane, it is almost certainly biogenic.
Pipeline natural gas is thermogenic. It formed over millions of years under heat and pressure deep underground, and that process produces heavier hydrocarbons alongside methane, chiefly ethane. Natural gas typically contains roughly 0.5% to 15% ethane by volume but this varies based on location.
Biogenic methane is made by microbes, and microbes make almost no ethane. Raw biogas from digesters is mostly methane and carbon dioxide, with ethane and other higher hydrocarbons often below 0.1%. That difference is why atmospheric scientists use the ethane-to-methane ratio to separate pipeline emissions from biogenic ones in city-scale studies.
Put simply, methane tells you something is there and ethane tells you what it is. Adding an ethane check converts an ambiguous indication into a yes-or-no answer while the crew is still on site, before anyone schedules a return visit or a dig.
Ethane is diluted along with methane. If your gas is 3% ethane and the reading is 50 ppm methane, the sample holds only about 1.5 ppm (1,500 ppb) of ethane. A test that needs percent-level gas will miss it; a test that reads in the hundreds of ppb will not. Detection threshold therefore decides how small a reading you can resolve in the field, and small, dilute readings are exactly the ones that end up ambiguous.
Methane tells you something is there. Ethane tells you what it is.
Four approaches are in use today. Each has a place. The right choice depends on
how small the readings are, how quickly you need an answer and what you can spend.
1 Percent-Level Ethane Analysis
Several combustible gas detectors include an ethane test. The instrument draws a sample and reports whether ethane is present. It is fast and it rides along on an instrument many crews already carry. Its limit is sample strength: one manufacturer states that the sample must be above roughly 1%, or at least 0.5%, natural gas for a reliable ethane result. That is 5,000 to 10,000 ppm.
2 Infrared Ethane Detection (SENSIT IRED)
A dedicated handheld that uses infrared absorption tuned to ethane, so it can measure ethane within a methane sample while filtering out other gases. The SENSIT IRED detects 250 ppb ethane in a 50 ppm methane sample and returns a result in minutes. It is built for the small, dilute readings that percent-level tests cannot resolve.
3 Laser-Based PPB Analyzers
Laser spectroscopy analyzers measure methane and ethane together, continuously, at parts-per-billion levels. They give real-time information while the operator walks the area and are well suited to pinpointing and to programs that log every reading. They are also the most expensive option, typically costing several times as much as a dedicated infrared ethane detector.
4 Laboratory Analysis
A sample bag sent to a lab can be analyzed for full composition and for methane isotopes, which is the most definitive attribution available. The trade-off is time. Results generally take one to two days, and the indication has to be treated as a real gas leak until they arrive. Lab analysis is the right tool for disputed or forensic cases, not for daily field decisions.
DIMENSION | PERCENT-LEVEL PROBE-HOLE TEST | INFRARED ETHANE (SENSIT IRED) | LASER PPB ANALYZERS | LABORATORY ANALYSIS |
|---|---|---|---|---|
Gas needed in sample | ~0.5-1% natural gas (5,000-10,000 ppm) | 250 ppb ethane in 50 ppm methane | Low ppb | Very low; lab-dependent |
Time to answer | Minutes | Minutes | Seconds, continuous | 1-2 days |
Tells pipeline gas from biogenic? | Yes, on strong samples | Yes, including dilute samples | Yes, in real time | Yes, most definitive |
Typical equipment cost | Often an option on a combination detector | $10,000 - $20,000 | Several times the IRED range | Per-sample fees plus shipping |
Best role | Confirm strong probe-hole readings | Confirm small or dilute readings on the same visit | Survey and pinpoint with live attribution | Disputed or forensic cases |
Main limit | Misses weak or dilute samples | Sample analysis requires several minutes | Highest cost and complexity | Too slow for field decisions |
Table 1
The ethane test assumes your pipeline gas is fossil gas. That assumption is weakening. Renewable natural gas is biogas from landfills, digesters and farms that has been cleaned up to pipeline quality. EPA describes pipeline-injected RNG as having “zero to very low levels” of ethane and other heavier hydrocarbons compared with fossil gas. EPA’s data show roughly 237 landfill and agricultural RNG projects operating in the U.S. in 2023, up from 13 in 2005.
In a segment fed mainly by RNG, a real leak could show little or no ethane at all. Three practical rules follow:
| Know your ratio. Record the ethane-to-methane ratio in each part of your system, and update it when RNG
supply changes.
| Treat “no ethane” near RNG injection as inconclusive. Use pressure data, odorant, a lab sample or a repeat survey before you
clear an indication.
| Favor lower detection thresholds where ratios are low. A reduced ethane fraction pushes the signal down, and a lower
threshold buys back margin.
The SENSIT IRED fills the gap between two kinds of tools. Percent-level tests are affordable but need a strong sample. Laser ppb analyzers resolve almost anything but cost several times more. The IRED confirms ethane on small, dilute readings at a price a district can justify on avoided dry runs alone.
Other practical features matter in the field. The IRED uses an internal pump to draw the sample, displays 0–999 ppb and 1.0–500 ppm ethane, logs readings and transmits over Bluetooth. That logged reading becomes the record behind a decision to clear or escalate.
SENSIT positions the IRED as the confirmation tier: the instrument a crew carries to settle whether an indication is
natural gas. This is more advanced than a Combustible Gas Indicator (CGI) with a pipeline gas discrimination feature. SENSIT is also developing a ppb-class handheld that measures methane and ethane together, for programs that want continuous attribution during the survey itself. The two serve different jobs. Utilities that need same-visit confirmation today do not need to wait for the next tier to start cutting dry runs.
A leak investigation costs the same whether or not it finds a leak. Most utilities do not track the cost of the ones that find nothing, so it stays invisible. The tables below build that cost from published inputs and stated assumptions.
Replace any line with your own figures.
For reference, published industry estimates for a single field dispatch range from about $150 to over $1,000 depending on distance, labor rates and time on site. Those estimates come from general field-service settings, so we built our own.
INPUT | LOW | HIGH | BASIS |
|---|---|---|---|
Technician rate | $62/h | $150/h | BLS median wage for gas plant operators. High: overtime or after-hours with full overhead. |
Time on task | 1 tech x 1.5 h | 2 techs x 2 h | 45 min on site plus travel and close-out paperwork |
Dispatch and supervisor | - | 0.5 h = ~$60 | Assumption |
Vehicle | 20 mi x $0.76 = $15 | 40 mi x $0.76 = $30 | IRS business mileage rate from July 1, 2026 |
Cost per visit | ~$110 | ~$690 | Sum of the rows above |
Repeat-visit factor | 1.0 | 1.5 | Unresolved readings are often revisited |
Cost per dry investigation | ~$110 | ~$1,000 | Cost per visit x repeat factor |
Table 2
ITEM | SOFT SURFACE, VACUUM EXCAVATION | PAVED STREET, CONVENTIONAL DIG | BASIS |
|---|---|---|---|
Crew time at $100/h | 2 x 4 h = $800 | 3 x 6 h = $1,800 | Burdened rate between the low and high technician rates. |
Excavation equipment | $1,000 - $1,900 | $800 - $1,200 | Vacuum truck at $235 - $485/h for 4 h; backhoe and dump truck (assumption) |
Traffic control | - | $300 - $1,000 | From ~$50/h to a flagging crew |
Locate, permit and admin | ~$200 | $200 - $1,000 | Varies by municipality |
Restoration | ~$300 | $1,500 - $5,000 | Turf versus permanent pavement patch |
Estimate per dry dig | ~$2,300 - $3,200 | ~$4,600 - $10,000 | Sum of the rows above |
Table 3
WHAT GETS AVOIDED | TO COVER $10,000 | TO COVER $20,000 |
|---|---|---|
Dry investigations ($110-$1,000 each) | 10-91 | 20-182 |
Soft-surface dry digs ($2,300-$3,200) | 4-5 | 7-9 |
Paved-street dry digs ($4,600-$10,000) | 1-3 | 2-5 |
Table 4
Worked examples: one district, one year (use your own figures)
A district closes 1,000 leak investigations a year. If 30% end with no gradable leak, that is 300 dry investigations. At
$110 to $1,000 each, they cost $33,000 to $300,000 a year.
If 1 in 20 of those escalates to a dig that finds no gas, that adds 15 dry digs. At $2,300 to $10,000 each, that is another
$34,500 to $150,000.
Combined, the non-productive spend is roughly $67,500 to $450,000 a year. An ethane test that resolves even a fraction
of the ambiguous cases on the first visit attacks both lines at once. The 30% rate and the 1-in-20 escalation rate are
illustrative; measure your own.
Dry runs cost money. A real leak written off as ‘swamp gas’ costs far more. Every supervisor knows the call that keeps them up at night: an indication near a sewer, a low reading, a crew that has seen a dozen of these turn out to be nothing. Clearing it without a test is a judgment call. If it was gas, that judgment will be reviewed by people who were not there.
An ethane check does not prevent incidents on its own. What changes is the basis for the decision. A crew that clears an indication with a logged ethane result has evidence, not a hunch, and a crew that finds ethane where it expected swamp gas has caught the leak that matters.
You get an answer before you leave the site. When a reading near a manhole or wetland can be checked for ethane on the spot, you can clear a biogenic source in minutes instead of opening a ticket and coming back. The IRED reads small readings, so the 50 ppm hit in the grass verge gets an answer too, not just the strong bar-hole readings. Your day produces more closed cases and fewer dead ends.
Source confirmation cuts the two costs you feel most: repeat visits and precautionary digs. Fewer ambiguous indications escalate, and the digs that do happen are more likely to find gas. Each decision to clear or escalate comes with a logged ethane reading, which is the record you want if a call is ever questioned. Where RNG enters your system, set a clear rule for when “no ethane” is enough and when it is not.
False positives are a recurring operating expense. An IRED in the $10,000–20,000 range pays back after a handful of avoided digs. Federal leak detection rules remain unsettled, but state programs and more sensitive survey technology are already increasing investigation volume. Measuring your non-productive rate now gives you the baseline to justify the spend and to defend your leak program to regulators.
A sensitive survey finds methane well. It cannot tell you whose methane it is. In published urban studies, a third to two-thirds of street-level indications were not pipeline gas, and every one of them can still cost a truck roll, a technician’s afternoon or a dig.
Ethane is the field test that closes that gap. The SENSIT IRED confirms it on readings as small as 50 ppm methane, far below what percent-level tests require, at a fraction of the cost of laser analyzers. Where RNG is in the mix, pair it with a known ethane ratio and a clear escalation rule.
The next step is to measure. Pull last year’s investigations and excavations, count how many found no gradable leak,
and apply your own labor, vehicle and restoration costs to the tables in this paper. Then talk to SENSIT about running the IRED alongside your current process and comparing the numbers.
Methane comes from many sources besides pipelines, including sewers, storm drains, wetlands, landfills and buried organic material. A methane detector cannot tell them apart. Published studies have attributed one-third to two-thirds of urban street-level methane indications to non-pipeline sources.
Test the sample for ethane. Pipeline natural gas contains ethane, typically around 0.5% to 15% by volume. Swamp, sewer and landfill gas contain little or none. Ethane present in the right proportion means pipeline gas; methane with no ethane is almost always biogenic.
Very little. Biogenic methane is produced by microbes, which make almost no ethane. Digester biogas typically carries ethane and other higher hydrocarbons below 0.1%.
No. A methane detector or combustible gas indicator measures methane or combustible gas concentration only. You need a second measurement, such as ethane, to identify the source.
Our bottom-up estimate is roughly $110 to $1,000 per investigation that finds no leak, depending on crew size, overhead, travel and repeat visits. An excavation that finds no leak runs roughly $2,300 to $10,000 depending on surface and restoration.
The IRED detects 250 ppb ethane in a 50 ppm methane sample. That is enough to confirm most pipeline gas on readings far smaller than percent-level probe-hole tests can handle.
Usually very little. EPA describes pipeline-injected RNG as 96% to 98% methane with zero to very low ethane. Where RNG enters your system, a real leak may show less ethane than you expect, so treat “no ethane” near injection points as inconclusive.
No. The survey instrument finds and locates methane. The ethane detector confirms whether that methane is natural gas. They work as a pair.